£ GBP

Agar Scientific

Microscopy and Lab
supplies at your fingertips

SEM 300nm reference standard

These 2-D holographic array standards for simultaneous calibration of X and Y axes have unique characteristics that make them easy to use for AFM, STM, Auger, FIB and SEM.

All prices exclude VAT.

These 2-D holographic array standards for simultaneous calibration of X and Y axes have unique characteristics that make them easy to use for AFM, STM, Auger, FIB and SEM.

There are two pitch sizes available:

The 144nm pitch, two dimensional array is accurate to ±1nm and is suitable for SEM and AFM calibrations. The pattern covers the entire chip enabling thousands of measurements to be made without revisiting the same scan area. The surface comprises aluminium ‘bumps’ on silicon. The bump height is approximately 90nm and width 75nm (not calibrated).

For SEM the 144nm standard works well at all accelerating voltages.

For AFM it can be used in contact, intermittent contact (TappingMode™) and other modes, with image sizes from 250nm to10mm.For AFM the2-D standard is available unmounted or can be mounted on 12 mm steel discs. The pattern is durable and allows for extended scanning in contact mode, which means that calibration and measurements are faster.

The 300 nm pitch reference standard is particularly useful for SEM, Auger and FIB calibrations. It can be used for a wide range of accelerating voltages (1kV - 20kV) and calibrates images from x5000 to x200,000 magnification. It can be also be used for AFM.

The surface structure is aluminium ‘bumps’ on silicon. The bump height is approximately 50nm and width 150nm (not calibrated).

The specimen is supplied with a non-traceable manufacturer’s certificate which states the average pitch based on batch measurements.

*Please send your stub(s) to: Agar Scientific Labs, Unit 7, M11 Business Link, Parsonage Lane, Stansted, Essex CM24 8GF United Kingdom

With contact details and quoting your web order reference number.

Description Code Stock Unit Price Qty
300nm calibration standard on 12.5 mm pin stub AGS1863 Lead time:
45 days
EA
£0.00
300nm calibration standard on 10 mm JEOL stub AGS1863A Lead time:
45 days
EA
£0.00
300nm calibration standard on 15 mm Topcon/ISI/ABT stub AGS1863B Lead time:
45 days
EA
£0.00
300nm calibration standard on 15 mm Hitachi stub AGS1863C Lead time:
45 days
EA
£0.00
300nm calibration standard on customer stub * AGS1863D Lead time:
45 days
EA
£0.00
300nm calibration standard on 12.5 mm JEOL stub AGS1863E Lead time:
45 days
EA
£0.00
300nm calibration standard, unmounted AGS1863U Lead time:
14 days
EA
£0.00
   

2d holographic array standards

  • 2d holographic array standards