Agar Scientific

Microscopy and Lab
supplies at your fingertips

Probes - OPUS Series

Probes - OPUS Series

Optimised Positioning Upon Sample

Special Tip Shape
The tip is located exactly at the end of the cantilever, which allows exact positioning of the tip apex over the region of interest on the sample surface.

Consistent cantilever and tip properties
State-of-the-art manufacturing process ensures consistency in cantilever and tip properties. High quality factor, smooth resonance curves, good cantilever reflectivity and excellent tip sharpness are some of the many advantages you can count on with every single OPUS silicon microcantilever.

Industry standard holder chips
OPUS microcantilever holder chips have industry standard dimensions (3.4 x 1.6 x 0.315mm) and fit all AFM systems that use unmounted probes. The individual cantilever models feature alignment grooves on the back surface of the chip.

High quality base silicon material

All OPUS silicon microcantilevers are manufactured from highly n-doped mono-crystalline silicon with resistivity in the range 0.01 - 0.025Ω-cm for static charge dissipation. The cantilever and chip surface is a (100) plane and the cantilevers point in the direction.

Set Descending Direction

Items 1-12 of 23

  1. AFM cantilever, no coating 300kHz 26N/m

    AFM cantilever, no coating 300kHz 26N/m

    More Information

    !NEW!

    Standard tapping mode AFM cantilever without coating. Topography measurement.

  2. High frequency cantilever, no coating 1200kHz 100N/m

    High frequency cantilever, no coating 1200kHz 100N/m

    More Information

    !NEW!

    High frequency tapping mode cantilever without coating. Topography measurement.

  3. High freqencey cantilever, Al reflective coating 1200kHz 100N/m

    High freqencey cantilever, Al reflective coating 1200kHz 100N/m

    More Information

    !NEW!

    High frequency tapping mode cantilever with Al reflective coating. Topography measurement.

  4. AFM cantilever, Al reflective coating 300kHz 26N/m

    AFM cantilever, Al reflective coating 300kHz 26N/m

    More Information

    !NEW!

    Standard tapping mode AFM cantilever with Al reflective coating. Topography measurement.

  5. AFM cantilever, Au reflective coating 135kHz 9N/m

    AFM cantilever, Al reflective coating 135kHz 9N/m

    More Information

    !NEW!

    Standard tapping mode AFM cantilever with Al reflective coating. Topography measurement.

  6. AFM cantilever, no coating 70kHz 2N/m

    AFM cantilever, no coating 70kHz 2N/m

    More Information

    !NEW!

    Soft tapping mode AFM cantilever without coating. Topography measurement.

  7. AFM cantilever, Al reflective coating 70kHz 2N/m

    AFM cantilever, Al reflective coating 70kHz 2N/m

    More Information

    !NEW!

    Soft tapping mode AFM cantilever with Al reflective coating. Topography measurement.

  8. Mixed AFM cantilevers, without coating, 17/150/75kHz, 0.3/9/2.5N/m

    Three AFM cantilevers, without coating, 17/150/75kHz, 0.3/9/2.5N/m

    More Information

    !NEW!

    Three AFM cantilevers without coating for various applications. Topography measurement.

  9. Mixed AFM cantilevers, Al reflective coating, 17/150/75kHz, 0.3/9/2.5N/m

    Three AFM cantilevers, Al reflective coating, 17/150/75kHz, 0.3/9/2.5N/m

    More Information

    !NEW!

    Three AFM cantilevers with Al reflective for various applications. Topography measurement.

  10. Mixed AFM cantilevers, without coating 17/75/150/1200kHz, 0.3/2.5/9/100N/m

    Four AFM cantilevers, without coating 17/75/150/1200kHz, 0.3/2.5/9/100N/m

    More Information

    !NEW!

    Four AFM cantilevers without coating for various applications. Topography measurement.

  11. High frequency cantilever, Au reflective coating 1200kHz 100N/m

    High frequency cantilever, Au reflective coating 1200kHz 100N/m

    More Information

    !NEW!

    High frequency tapping mode cantilever with Au reflective coating. Bio and special applications.

  12. AFM cantilever, Au reflective coating 300kHz 26N/m

    AFM cantilever, Au reflective coating 300kHz 26N/m

    More Information

    !NEW!

    Standard tapping mode AFM cantilever with Au reflective coating. Bio and special applications.

Set Descending Direction

Items 1-12 of 23